EXAPEN manual

Last revision date 13/08/2024

Connecting Power to the Device

Connect the RED clip to the battery's positive pole and the BLACK clip to the negative pole of the battery.

The RED banana connector must be connected to the socket marked “+”, and the BLACK connector to the socket marked “-”. There is a built-in protection against polarity reversal for cases when you mix up the wires.

Exapen operates only from the vehicle battery, either 12 or 24 volts. There are no additional power sources. All measurements are made relative to the negative terminal of the battery. The activation signals of the actuators are supplied from the battery through the device protection system. 

We recommend using the original cable that comes with the device, as it has connectors with caps to protect the contact group from accidental touching of metal surfaces. The cable also has built-in fuses that provide additional protection for the cable in case of a short circuit of the connectors on the side connected to the device.
 